Breaker ID Tags
Circuit breaker labels for the breaker box or panel: numbers, feeders and loads
Breaker Labels
Circuit breaker labels for the breaker box or panel: numbers, feeders and loads
Fire alarm, emergency lighting, sump pumps: red so nobody shuts them off
UPS, PDU and RPP breakers, A side and B side
From a 1 in handle tag to a 6 × 3 in switchboard plate
149 engraved labels in 9 categories: breakers, panels, data centres, MCCs, arc flash, lockout, solar and EV. Each one is checked against the laser file and opens in the label maker to edit.
Browse All Labels
Blue for A, red for B, the same on every rack, PDU and whip so a tech never pulls the wrong feed.
Unit ID, rating and source on every UPS module, static switch, ATS and remote power panel.
Send the one-line or the panel schedules. We engrave every label as a matched set and ship it sorted by room.
Panel schedules turned into engraved tags for new builds, retrofits and inspection punch lists.
A and B feeds, UPS, PDU and RPP labels, engraved as one matched set per room.
Backfed PV breakers, EV charger circuits and rapid shutdown labels.
Type the circuit, pick a size and colour, and order. The preview is drawn from the laser file we cut, and the price updates as you type.
Still unsure? Call 289-275-9572 or send your schedule through the quote form below.
Turn on every light and outlet, then switch breakers off one at a time and note what goes dark. Give each breaker its circuit number and load (CCT 14 KITCHEN COUNTER, RTU-1), mark spares as SPARE, and use red for anything that must stay on. Then engrave the list so it outlives the pencil on the door.
The circuit number or numbers, and what the breaker feeds: RTU-1, LP-2A, EV CHARGER 1. For feeders and mains add the rating and where it is fed from. The Canadian Electrical Code (Rule 2-100) asks for every circuit to be identified, and an engraved tag is the label that is still readable at the next inspection.
A lamacoid is a two-ply engraving laminate: a coloured top layer over a contrasting core. The laser cuts through the top layer to expose the core, so the lettering is part of the tag instead of ink or vinyl sitting on top of it. No fading, no peeling, no smudged marker.
Black with white letters is the usual standard for breaker and panel ID. Red is used for fire alarm, emergency and do-not-turn-off circuits, and in data centres blue and red mark the A and B feeds. Follow your spec where it names colours; every stocked pair is available.
Most orders are cut the same day you approve the artwork proof. Pick up free in Burlington, or ship anywhere in Canada by Canada Post.
Yes. Send the panel schedules or one-line through the quote form and we engrave every label as a matched set, one size and one letter height, sorted by panel or room.